1.5 KiB
1.5 KiB
title | timestamp | tags | |
---|---|---|---|
Conversion Table - Note | 15.08.2025 - 16:59 |
|
Conversion Table
[!info] Logarithmic Conversion Definition of Bell: $1B = \log_{10}\frac{P_1}{P_2}$ Therefor a Dezibell:
P_{dB} = 10\cdot\log_{10}\frac{P_1}{P_2} \longleftrightarrow \frac{P_1}{P_2} = 10^\frac{P_{dB}}{10}
Value Conversion according to:
P_{dB} = 10 \cdot \log_{10} x
Value | DB | Note |
---|---|---|
2 | 3 | |
4 | 6 | |
5 | 7 | |
10 | 10 | |
0.2 | -7 | \frac{1}{5} |
0.5 | -3 | \frac{1}{2} |
Dezibel Units
[!info]
dBm
& $dBW$ decibel millitwatt measurement of Power level $P_{dBm}$ Ratio for PowerP
compared to1mW
P_{dBm}=10\cdot\log_{10}\frac{P}{1mW}dBm
decibel Watt similar but for the reference
1W
P_{dBW}=10\cdot\log_{10}\frac{P}{1W}dBW
[!warning] Conversion
P_{dBm}= P_{dBW} -30
Cell Parameter Configurationen
[!info] SIR - Signal to Interference Ratio
SIR = \frac{1}{6} (3k)^{\frac{\gamma}{2}}
Cluster Size k:
k = \frac{1}{3}(\frac{D}{R})^2
with D:
D = R \cdot \sqrt{3k}
Testing k is done by:
k = i^2 + ij + j^2; \quad i,j\in\mathbb{N}